Panamax POWER-PRO INS00809 User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
Specifications are subject to changes due to product upgrades and improvements.
Panamax
1690 Corporate Circle
Petaluma, CA 94954
Phone - 707-283-5900 or 800-472-5555
Fax - 707-283-5901
Web - www.panamax.com
Customer Relations
7:30 AM – 4:30 PM, M-F Pacific Time
Power Outlet Faceplate
AC Connectors: ............................2 NEMA 5-15
Noise Filtration: ......................................Level 1
Signal Line Protection: Not Included / Modules
Sold
Separately
2
MIW-POWER-PRO SPECIFICATIONS
AC Circuit
AC Outlets, Total: ..................................................2
Line Voltage: .....................................120V, 50/60Hz
Total Current Capacity: .....................................15A
UL 1449 Suppression Rating: ........................330 V
Protection Modes: .............................L-N, L-G, N-G
Energy Dissipation: ................................546 Joules
Peak Impulse Current: ...............................32,500A
Catastrophic Surge Circuit: ...............................Yes
Thermal Fusing: ................................................Yes
Over-voltage shutoff: ....................142VAC ± 5VAC
CONTENTS
CONTACTING PANAMAX
POWER ON
LINE FA ULT
One MAX In-Wall
power outlet
enclosure
(4) Mounting Screws
(3) Wire Nuts
Included Installation Accessories:
Page view 1
1 2

Comments to this Manuals

No comments